#TEST 01: TCP and RS232. # - TCP = Remote IO Delta RTU-EN01, 24 inputs, 8 outputs. # - RS232 = Servo Drive Delta ASDA-B (1021-A 1Kw). [MB2HAL_INIT] INIT_DEBUG=2 SLOWDOWN=0.0 TOTAL_TRANSACTIONS=9 [TRANSACTION_00] LINK_TYPE=tcp TCP_IP=192.168.2.10 TCP_PORT=502 MB_SLAVE_ID=1 FIRST_ELEMENT=0 NELEMENTS=16 MB_TX_CODE=fnct_03_read_holding_registers HAL_TX_NAME=remoteIOcfg MAX_UPDATE_RATE=10.0 DEBUG=1 [TRANSACTION_01] MB_TX_CODE=fnct_02_read_discrete_inputs FIRST_ELEMENT=1024 NELEMENTS=24 HAL_TX_NAME=remoteIOin MAX_UPDATE_RATE=10.0 DEBUG=1 [TRANSACTION_02] MB_TX_CODE=fnct_15_write_multiple_coils FIRST_ELEMENT=1280 NELEMENTS=8 HAL_TX_NAME=remoteIOout MAX_UPDATE_RATE=10.0 [TRANSACTION_03] LINK_TYPE=serial SERIAL_PORT=/dev/ttyS0 SERIAL_BAUD=115200 SERIAL_BITS=8 SERIAL_PARITY=none SERIAL_STOP=2 SERIAL_DELAY_MS=50 MB_SLAVE_ID=1 MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=1 NELEMENTS=2 HAL_TX_NAME=XDrive01 MAX_UPDATE_RATE=10.0 DEBUG=1 [TRANSACTION_04] MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=4 NELEMENTS=3 HAL_TX_NAME=XDrive02 MAX_UPDATE_RATE=10.0 DEBUG=1 [TRANSACTION_05] MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=9 NELEMENTS=1 HAL_TX_NAME=XDrive03 MAX_UPDATE_RATE=10.0 [TRANSACTION_06] MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=1024 NELEMENTS=1 HAL_TX_NAME=XDrive04 MAX_UPDATE_RATE=10.0 [TRANSACTION_07] MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=1030 NELEMENTS=2 HAL_TX_NAME=XDrive05 MAX_UPDATE_RATE=10.0 [TRANSACTION_08] MB_TX_CODE=fnct_03_read_holding_registers FIRST_ELEMENT=1033 NELEMENTS=1 HAL_TX_NAME=XDrive06 MAX_UPDATE_RATE=10.0